ติดต่อเรา 08.00 - 17.30
โทร 02-943-0180 ต่อ 120
Product categories

UPS (เครื่องสำรองไฟฟ้า) CYBER POWER CBP-OLS3000EC-AS 3000VA/2400W

รหัสสินค้า : SIS3622107271028

฿21,800

โทรสอบถามราคา
การรับประกัน :
Data Sheet :
SIS3622107271028_datasheet.pdf

ราคาสินค้าไม่รวมภาษีมูลค่าเพิ่ม

ติดต่อสอบถามราคาพิเศษ

Line : 
Tel : 099-495-8880
Facebook : https://www.facebook.com/gtoengineer/
Email : support@gtoengineer.com

อัปเดตล่าสุด : 5 days ago

GENERAL

Phase

Single Phase
Form Factor

Tower
UPS Topology

Online Double Conversion
Energy Saving Technology

Online ECO Mode Efficiency > 95%
Active PFC Compatibility

Yes

INPUT

Generator Compatibility

Yes
Nominal Input Voltage ( Vac )

230 ? 10%
Input Voltage Range ( Vac )

190 ~ 300
Adjustable Voltage Range ( Vac )

0~50% Load for 110 ~ 300 Vac
0~60% Load for 140 ~ 300 Vac
0~80% Load for 160 ~ 300 Vac
0~100% Load for 190 ~ 300 Vac
Input Frequency ( Hz )

50 ? 10
60 ? 10
Input Frequency Detection

Auto-sensing
Rated Input Current ( A )

13.6
Input Power Factor

0.98
Input Connector Type

IEC C20
Plug Style

Straight
Detachable Power Cord Plug Type

Schuko x 1
Power Cord Length (ft.)

4
Power Cord Length (m.)

1.2

OUTPUT

Capacity (VA)

3000
Capacity (Watts)

2400
On Battery Waveform

Pure Sine Wave
On Battery Voltage(s) ( Vac )

208 ? 1%
220 ? 1%
230 ? 1%
240 ? 1%
Output Voltage Setting

Configurable
On Battery Frequency ( Hz )

50 ? 0.5%
60 ? 0.5%
Output Frequency Setting

Configurable
Power Factor

0.8
ECO Mode Voltage Tolerance

? 15 %
Overload Protection

Internal Current Limiting, Circuit Breaker, Fuse
Overload Protection (Line Mode)

110~120% Load for 1 min, >120% Load Immediately
Overload Protection (Battery Mode)

110~120% Load for 10 sec, >120% Load Immediately
Overload Protection (Bypass Mode)

>130% Load Immediately
Crest Factor

3 : 1
Harmonic Distortion (Linear Load)

THD?3%
Harmonic Distortion (Non-linear Load)

THD?5%
Internal Bypass

Automatic Bypass, Manual Bypass, 50(Default)/60Hz, -10% to +10% of Nominal Input Frequency
Outlet(s) – Total

5
Outlet Type

Hardwire Terminal Block x 1
IEC C13 x 4
Outlet(s) – Battery & Surge Protected

4
Outlet(s) – Critical Load (CL)

5
Typical Transfer Time ( ms )

0

BATTERY

Runtime at Half Load ( min )

10
Runtime at Full Load ( min )

3.5
Typical Recharge Time ( Hours )

4
Start On Battery

Yes
Smart Battery Management (SBM)

Yes
User-replaceable

No
Battery Type

Sealed Lead-acid
Battery Quantity (Each RBP) ( pcs )

6
Battery Voltage (Each RBP) ( V )

72

SURGE PROTECTION & FILTERING

Surge Suppression ( Joules )

220
EMI/RFI Filtration

Yes

MANAGEMENT & COMMUNICATIONS

LED Indicators

Power On, Line Mode, Battery Mode, Bypass Mode, Battery Capacity, Low Battery, Overload, UPS Fault, Replace Battery
HID Compliant USB Port(s)

1
Audible Alarms

Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery
Management Cable ( pcs )

Power Cord x2, USB Cable x1
Power Management Software

PowerPanel? Business (Recommended)

PHYSICAL

Enclosure Construction

Metal
Color

Black

PHYSICAL SIZE – UPS MODULE

Dimensions (WxHxD) (in.)

7.72 x 12.27 x 16.38
Dimensions (WxHxD) (mm.)

196 x 337 x 416
Weight (lbs.)

62.17
Weight (kg.)

28.2

 

GreenPower UPS?

GreenPower UPS? Technology improves operating efficiency and minimizes energy consumption, so that users can enjoy significant energy cost savings over conventional UPS systems.

 

 


source : https://www.cyberpower.com/th/en

?????????? ????????????????????????????? ????????????????????????????????????,????????????????????????? (???/??)

?????????? ?????????????????????????????????????? ??????????????????????????????????? ????????????????????????????????????????????????????????? ??????
1. ???????????????????????????????????????????????
2. ?????????????????????????????????
*** ?????????????????????????????????? ??????????????????????????????
???????????????? Call Center 02-017-4444 ????  @jib online

ขอใบเสนอราคา